Description: HIGH ACCURACY- Measuring range 120m/393.7ft, measuring accuracy up to +/- 2.0mm, single measurement time is 0.5s, laser type is 500~690nm with grade II, <1MW. Operation1.Switch-onShort press to switch on the equipment,and laser point is opened at the same time.indication as shown as figure A. Laser point is automatically shut down if no any operation after 30seconds.Or short press to close the laser point, indication as shown as figure B. Short press again to open laser point, indication as shown as figure A .2.Change Measurement ReferenceDefault measuring reference is the bottom of meter,indication as shown as figure A . Long press to change the measuring reference to the top of meter,indication as shown as figure C.3. Unit Conversion Factory default that unit is m, indication as shown as figure A. Long press to switch unit m to Ft, indication as shown as figure D. Long press again to switch the unit Ft to In, indication as shown as figure E. (Note: Long press to switch the unit of measurement will switch the value at the same time if it has value of measurement.)When the unit of measurement is m², long press to switch the unit to ft²,long press again to switch the unit to In².When the unit of measurement is m³,long-time press to switch the unit to ft³,long press again to switch the unit to In³.4.Change Measurement Mode Default setting of measurement is single measurement mode, indication as shown as figure A. Short press to switch area measurement mode, indication as shown as figure F.Short press again to switch volume measurement mode, indication as shown as figure G . Short press again to switch pythagoras measurement mode to measuring height, indication as shown as figure H. Short press again to switch Height Difference pythagoras measurement mode ,indication as shown as figure I. Short press again to switch Historical Data Review mode,indication as shown as figure J. 5. Switch off The equipment can be switched off at any time by long time press .6. Historical Data Scroll up Check/Data ClearIn Historical Data Review mode ,measuring data indication as shown as figure K. Short press or Short press to the historical reading one by one forward .Bigger number means the newer measuring value, indication as shown as figure L. Short press ,delete measuring data records one by one forward.(Note:The equipment can store the most recent 20 measuring data. At this time, it will measure data storage records that factory tested. It not means this equipment has been used.) 7. Single measurement of distance between two pointsIn the single measurement mode, aim the laser onto target Short press . The result willbe displayed immediately as shown as figure M. 8. Continuous measurement of distance between two PointsIn the state of switch-on, long press to enter the continuous measurement mode, indication as shown as figure O. 9. Area MeasurementIn the area measurement mode and aim the laser onto target.Short press to measure the two side lengths of the target respectively,area measurement results will be displayed as shown as figure P. 10. Volume MeasurementIn the volume measurement mode and aim the laser onto target. Short press and measure the three side lengths of the target respectively. The result will be displayed immediately as shown as figure Q. 11. Plus and Minus Functions When the equipment is switched on, indication as shown as figure A . Short press , the current measurement result is added to the previous one and the indication as shown as figure R .Short-time press , the current measurement result is subtracted from the previous one, as shown in figure S .(Note: The default previous measurement value is 0.000m) When measuring area and volume, short-time press or , the current measurement result is added to or subtracted from the previous one also.12. Height Measurement(Pythagorean Theorem)In the Height Measurement (Pythagorean Theorem) mode,the meter is in the horizontal position and aim the laser onto the bottom of the target . Short press to measure the right-angle side length of the triangle.Then keep the reference point of the meter unchanged and aim the laser onto the top of the target .Short press again to measure the length of the hypotenuse of a right triangle. The height value of the right triangle is displayed immediately on the screen as shown as figure T. 13. Mute ModeWhen the equipment is switched on ,the default setting of buzzer is switched on. The equipment will beep when measuring . Long press , hear “beep”, the mute mode switch on, the equipment will not beep when measuring .14.Height Difference Measurement(Pythagorean Theorem)In the height difference measurement(Pythagorean Theorem) mode,the meter is in the horizontal position and aim the laser onto the datum of the target. Short-time press to measure the right-angle side length of the triangle.Then keep the reference point of the meter unchanged and aim the laser onto the bottom of the target . Short-time press again to measure the second length of the hypotenuse of a right triangle.Then keep the reference point of the meter unchanged and aim the laser onto the top of the target .Short-time press again to measure the first length of the hypotenuse of a right triangle.The height value of the right triangle is displayed immediately on the screen as shown as figure U Notes All the pictures used in the manual are only illustrative illustrations, not the actual display of the equipment.
Price: 92.99 USD
Location: Cherry Hill, New Jersey
End Time: 2025-01-30T09:02:01.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Working time(Fully charged ): >5000 times
Historical Data Records: 20Groups
Item Length: 5 in
Measuring Range: 120m: 0.05m~120m
Manufacturer Warranty: 1 Year
Item Height: 2"
Measuring Technology: Laser
Features: Battery Included, Compact/Pocket-sized, Continuous Measurement, Dust-proof, Hand Strap, Hard Rubber Body, LCD Display, Low-battery Indication, Measurement of Area, Measurement of Length, Measurement of Volume, Non-Slip Material, Portable, Self-leveling, Waterproof
Unit Quantity: 1
Measuring Accuracy(Standard Deviation): ±2.0mm
Item Width: 2"
Storage Temperature: -20°~+65°
Operating Temperature: -10°~+40°
Weight (Without batteries): 150g
Switch off: 120s
Distance Unit: m ft in
Single Measurement Time: 0.5s
Color: Green
Item Diameter: 5"
Material: Plastic
Brand: Surgoal
Type: Distance Measurer
Laser Class: class II
Country/Region of Manufacture: China
Item Weight: 5 oz