Description: Allen Bradley SMC-3 150-C37NCD Ser B Soft Starter Smart Motor Controller No Fan AB 150-C37NCD 3-Phase Soft Starter These are factory spares, no box included. They also do not have the fan. (fan model is included in pictures so you can order.) Voltage type for actuating AC/DC Rated operating voltage Ue 200 V Rated control supply voltage at AC 50 Hz 100 V Rated control supply voltage at AC 60 Hz 100 V Overload current 12.3 A Controller type SMC-3 DV/DT protection 1000V/µs for power circuit Repetitive peak voltage 1600V per UL/CSA/NEMA for power circuit Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit Line connected motor power, max 22 kW @ 500V AC, 50 Hz, 3-phase Delta connected motor power, max 15...60 Hp @ 575V AC, 60 Hz, 3-phase Overvoltage category III per IEC for side mount auxiliary contacts Rated impulse voltage 6 kV for power circuit Dielectric withstand 2500V AC per IEC for power circuit Line connected motor current 12.3...37 A @ 500/575V AC, 3-phase Delta connected motor current 21...64 A @ 500/575V AC, 3-phase Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts Rated control power during start with fan 215 mA @ 120V AC/180 mA @ 240V AC, 800 mA @ 24V DC/660 mA @ 24V AC Input OFF-state current <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts High capacity available fault current, max 70 kA @ 600V, maximum current 60 A time delay Class J or Class L fuse for line connected motors Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6 A @ 120V AC and 0.3 A @ 240V AC for auxiliary contacts Standard controller feature Soft stop Standard available fault current, max 10 kA @ maximum standard fuse 250 A for delta device operational current rating Integrated motor overload protection Yes Short circuit protection device performance (SCPD) type Type 1 Selectable overload trip class Trip Class 10, 15, or 20 Selectable start times 2, 5, 10, 15, 20, 25, or 30 s Input OFF-state voltage (IN1, IN2), max 40V AC, 17V DC/12V AC for control circuit Selectable current limit 150%, 250%, 350%, and 450% of full load current Input ON-state voltage, during start (IN1, IN2) 85V AC, 19.2V DC/19.2V AC minimum for control circuit Rated control power during start without fan 205 mA @ 120V AC/145 mA @ 240V AC, 705 mA @ 24V DC/580 mA @ 24V AC Input ON-state current (IN1, IN2) 9.8 mA @ 120V AC/19.6 mA @ 240V AC for control circuit, 7.3 mA @ 24V AC/DC for control circuit If there's something you're not sure about or have a question about anything, just send us a message by clicking "Ask a question" below the listing. Free Shipping is only for the inner 48 states (Large Freight Shipments Do Not Apply). ,
Price: 367.99 USD
Location: Fort Smith, Arkansas
End Time: 2025-01-20T20:04:53.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Return policy details:
Brand: Allen Bradley
MPN: 150C37NCD