Revere

DATAKOM DPR-02 Voltage Protection Controller, L-N, UV/OV

Description: WE DO NOT SHIP THIS PRODUCT FOR USAGE IN THE USA. DPR-02 relay is a three-phase (line to neutral) voltage protection relay designed to be used for over-voltage, under-voltage and phase rotation protection in distribution substations, generators, motors, transformers and capacitors in compensation systems. It offers adjustable over / under voltage limits together with adjustable trip and reset delays. The unit has also phase sequence protection. Both over voltage limit(Max) and under voltage limit(Min) can be adjusted or disabled via trimmers on the front panel of the device. Delay timers are adjusted through related trimmers. FEATURES: - DIN Rail mounted - Adjustable under voltage limit (L-N) - Adjustable over voltage limit (L-N) - Adjustable TRIP and RESET Delays - Phase sequence protection - Phase failure protection - Overvoltage protection - Insufficient supply protection - 6A/277VAC relay output. TECHNICAL SPECIFICATIONS: Nominal Supply Voltage: 230V-AC (L-N) Supply Voltage Range: 150-300 V-AC (L-N) Supply type: Capacitive, 3 phase Frequency Range: 47-63Hz Power Consumption: 30VA / 2W (max) Measurement method: True RMS, line to neutral Voltage Adjustment Accuracy: 3 % Repetition Accuracy: 0.5 % Over-Voltage Trip: 240-300 V-AC (L-N) adjustable Under-Voltage Trip: 150-210V-AC (L-N) adjustable Trip Delay Setup: 0.5 - 20 sec. adjustable Reset Delay Setup: 0.5 - 20 sec. adjustable Relay Output: 6A @ 277V-AC, 1800VA, 300W Terminal wire range: max 2.5mm² (12AWG) Screw-on Force: 0.4 Nm (3.6 lb.in) Operating temp.: -30°C (-22°F) to 70 °C (158°F). Storage temp.: -40°C (-40°F) to 80 °C (176°F). Maximum humidity: 95% non-condensing. Dimensions: 36,0x90,6x58,4mm (WxHxD) Weight: 100 gr(approx.) Installation: DIN Rail mounted. Case Material: High Temp. ABS/PC (UL94-V0) IP Protection: IP30 Conformity (EU directives) -2006/95/EC (low voltage) -2004/108/EC (EMC) Norms of reference: - EN 61010 (safety requirements) - EN 60255-6 - EN 61326 (EMC requirements)

Price: 79 USD

Location: Ljubljana

End Time: 2024-02-26T13:51:40.000Z

Shipping Cost: 0 USD

Product Images

DATAKOM DPR-02 Voltage Protection Controller, L-N, UV/OVDATAKOM DPR-02 Voltage Protection Controller, L-N, UV/OVDATAKOM DPR-02 Voltage Protection Controller, L-N, UV/OV

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Brand: Datakom

Equipment Type: Genset Controller

Country/Region of Manufacture: Türkiye

MPN: Does Not Apply

Recommended

DATAKOM DSD-060 Earthquake Shutdown Detector with seismic activity sensor
DATAKOM DSD-060 Earthquake Shutdown Detector with seismic activity sensor

$232.00

View Details
DATAKOM Genset Synchronization Module for D-500,700 MK2, MK3 Controllers (L060H)
DATAKOM Genset Synchronization Module for D-500,700 MK2, MK3 Controllers (L060H)

$294.00

View Details
DATAKOM WIFI PLUG-IN Module for D-XXX MK2, MK3 Controller series
DATAKOM WIFI PLUG-IN Module for D-XXX MK2, MK3 Controller series

$107.00

View Details
Datakom DKG 116 Generator Controller
Datakom DKG 116 Generator Controller

$130.00

View Details
DATAKOM DKM-401 Digital Multimeter Panel, 96x96mm, 3 Phase
DATAKOM DKM-401 Digital Multimeter Panel, 96x96mm, 3 Phase

$105.00

View Details
DATAKOM DFC-0108 power factor controller (8 steps) 96x96mm
DATAKOM DFC-0108 power factor controller (8 steps) 96x96mm

$229.00

View Details
DATAKOM DKG-207/217/227 RS-232 adapter & cable
DATAKOM DKG-207/217/227 RS-232 adapter & cable

$42.00

View Details
SMARTGEN HGM6120N Automatic Start Generator Controller (AMF)_
SMARTGEN HGM6120N Automatic Start Generator Controller (AMF)_

$337.15

View Details
DATAKOM COMM PLUG-IN MODULE with Ethernet, RS-485 and USB Host
DATAKOM COMM PLUG-IN MODULE with Ethernet, RS-485 and USB Host

$101.00

View Details
DATAKOM DVF-0303 digital voltmeter and frequency meter (3 Phase)
DATAKOM DVF-0303 digital voltmeter and frequency meter (3 Phase)

$79.00

View Details