Description: THIS IS A OPHTHALMIC PRODUCT BUYER AUTHORIZED BY FDA ONLY THEY BUY THIS PRODUCTTHIS IS A OPHTHALMIC PRODUCT .BUYER AUTHORIZED BY FDA ONLY THEY BUY THIS PRODUCTAttention International Buyers: Import duties, taxes and brokerage charges are not included in the item price or shipping charges. These charges are the buyers responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. Customs Clearance is buyers responsibility. Thank YouTABLET DISINTEGRATION DOUBLE TEST APPARATUSBest qualityVoltage 220/230 VPhase Single PhaseFrequency 50 HzAutomation Grade Semi-AutomaticPower Source Electric * PLACE THE APPARATUS ON A FIRM AND STABLE SURFACE.* INSTALL THE DT BASKET SUPPLIED WITH THE APPARATUS.* PUT 2-3 DROPS OF LUBRICATING OIL AROUND THE BASKET HOLDING ROAD.* CONNECT THE APPARATUS WITH ELECTRIC SUPPLY WITH PROPER EARTH CONNECTION.* START THE APPARATUS AND CHECK THAT BASKET IS MOVING PROPERLY.* FILL THE MEDIA IN BEAKER AS PER YOUR REQUIREMENT AND PLACE IT ON THE HOT PLATE OF THE APPARATUS.* DT APPARATUS IS READY FOR USE CONTROLS AND INDICATIONMAINS SWITCH: IT IS USED TO SWITCH OFF / ON THE APPARATUS.MOTOR SWITCH: IT IS USED TO SWITCH OFF / ON THE MOTOR.LED INDICATOR: INDICATES THAT SUPPLY TO HEATER IS ONHEATING CONTROL:HEATING IS CONTROLLED THROUGH ENERGY REGULATOR. HEATER IS CONTINUOUSLY ON AT 100% POSITION AND OFF AT OFF POSITION. HEATING ON AND OFF POSITION IS INDICATED BY RED INDICATOR WORKING:* FILL THE BEAKER WITH MEDIA SUITABLE FOR YOUR TABLETS AND PLACE ON THE HOT PLATE OF THE APPARATUS.* SWITCH ON THE APPARATUS BY PUTTING THE MAINS SWITCH AT ON POSITION.* SWITCH ON THE HEATER BY PUTTING THE HEAT CONTROL REGULATOR KNOB AT 100% POSITION. WAIT FOR 10-15 MINUTES* PUT THE REGULATOR KNOB AT 40% POSITION.* CHECK THE TEMPERATURE OF MEDIA WITH A THERMOMETER AND ADJUST THE HEATING AS PER REQUIRED TEMPERATURE. (NORMALLY 37 DEGREE) REDUCE THE % HEATING IF ACTUAL TEMPERATURE IS MORE THAN REQUIRED TEMPERATURE OR VICE VERSA.* PUT THE SAMPLE TO BE TESTED IN SAMPLE BASKET AND ATTACH IT WITH BASKET HOLDING ROAD.* SWITCH ON THE MOTOR BY MOTOR SWITCH.* SAMPLE BASKET WILL START MOVING UP AND DOWN. PRECAUTIONS:• MAKE SURE THAT WATER IS NOT DROPPING ON HOT PLATE WHILE ATTACHING AND REMOVING THE BASKET OR BEAKER.• DO NOT SWITCH ON THE HEATER WITHOUT PLACING BEAKER ON THE HOT PLATE.• DO NOT ATTACH AND REMOVE BASKET WHILE MOTOR IS ON. TROUBLE SHOOTING: IT IS OBSERVED THAT BASKET DOES NOT MOVE UP AND DOWN PROPERLY SOMETIMES DUE TO JERK DURING TRANSPORTATION. PLEASE TRY FOLLOWING.• REMOVE THE BASKET AND PULL THE BRASS ROD UP-SIDE.• CLEAN IT WITH CLOTH / DUSTER• PUT SOME LUBRICATING OIL (1DROP EACH SIDE) AROUND THE BRASS ROD NEAR BLACK COLOR ROD HOLDING GUIDE.• MOVE THE ROD UP-AND DOWN BY HAND ABOUT 8-10 TIMES.• PULL THE ROD UP SIDE AND CLEAN WITH CLOTH / DUSTER• PUT SOME LUBRICATING OIL (1DROP EACH SIDE) AROUND THE BRASS ROD NEAR BLACK COLOR ROD HOLDING GUIDE. THIS WILL SOLVE THE PROBLEM IN MOST OF THE CASES. TRY FOLLOWING IF PROBLEM IS STILL THERE.• REMOVE THE UPPER BACK SIDE PLATE BY REMOVING SCREWS HOLDING THE PLATE.• LOOSE THE BLACK GUIDE HOLDING SCREWS.• ALIGN THE GUIDE SO THAT BRASS ROD MOVES FREELY.• TIGHTEN THE GUIDE HOLDING SCREWS• FIX THE UPPER BACK PLATE.TERMS AND CONDITIONSITEM PARCELPlease provide full and correct shipping address and valid contact informationFEEDBACKYour feedback is important for growing our business on eBay, so do leave us afeedbackTHANK YOU
Price: 350 USD
Location: AMBALA, HARYANA
End Time: 2024-08-03T04:48:59.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: zaiss
MPN: Does not apply
Intended Use/Discipline: Biological Laboratory